XOS Clora R Analyzers
This state-of-the-art technology complies with ASTM D7536 and D4929C and delivers unparalleled accuracy and precision for petroleum and petrochemical applications where simple, quick, and reliable analysis is critical.
![](/templates/yootheme/cache/80/XOS_Clora_R_Series_-80ee5ff1.jpeg)
![](/templates/yootheme/cache/a2/XOS_Clora_analyzer_detail-a2c661a1.jpeg)
Analyze Total Chlorine with Unparalleled Precision
The Clora R compact analyzer measures total chlorine in hydrocarbons such as aromatics, distillates, heavy fuels, crude oils, and water.
Easier to use than ever, Clora 2XP R analyzes total chlorine in liquid hydrocarbons such as aromatics, distillates, heavy fuels, and crude oils, as well as aqueous solutions, while automatically correcting for Sulfur interference.
-
Applications
Clora R:
- Total chlorine analysis in petroleum products, biofuels, aromatics, and other chemicals, and water
- For refineries, petrochemical and additive plants, pipeline terminals, and test laboratories
Clora 2XP R:
- Total chlorine analysis from aqueous solutions and aromatic products to heavy fuels and crudes
- For refineries, petrochemical and additive plants, pipeline terminals, and test laboratories
-
Benefits
- LIMS integration for data management and transfer
- Custom sample presets to save data entry time and minimize data entry error on common samples
- Bar code reader auto fills sample name to reduce data entry time
- Storage capacity for more than 50,000 measurement results
- Supports up to 30 calibration curves
- USB connectivity in front and back for connecting to printer, keyboard, mouse, and memory stick
- Supports USB and network printers
- Large, easy-to-remove side panels for easy serviceability
- Advanced error reporting and diagnostics
-
Downloads
-
Features
Clora R Analyzer
- LOD: 0.13 mg/kg (ppm) at 300s, 0.09 mg/kg (ppm) at 600s for hydrocarbons, 0.3 mg/kg (ppm) at 300s, 0.2 mg/kg (ppm) at 600s for aqueous samples **
- Dynamic Range: 0.13 mg/kg (ppm) to 4 wt%
- Manual sulfur correction to correct for high sulfur interference
- Easy to use:
- Intuitive 10-inch touch screen
- Just plug in and measure
- Measurement time: 10-999 s
- Low and high range available:
- Low range: 0.13 mg/kg (ppm) – 3000 mg/kg (ppm)
- High range: 0.3 wt% - 4 wt%
- Extremely low maintenance: no gasses, heating elements, columns, or quartz tubing
- Traditional XRF sample cups or XOS Accucells – decided at time of order
- Small footprint
Clora 2XP R Analyzer
- LOD: 0.1 mg/kg (ppm) at 300s, 0.07 mg/kg (ppm) at 600s in hydrocarbons**
- Range: 0.1 mg/kg (ppm) – 2 wt%
- Automatic sulfur correction saves time and improves accuracy and precision on high sulfur samples
- Easy to use:
- Intuitive 10-inch touch screen
- Just plug in and measure
- Measurement time: 10-999 s
- Low and high range available:
- Low range: 0.1 mg/kg (ppm) – 3000 mg/kg (ppm)
- High range: 0.3 wt% - 2 wt%
- Low maintenance: no gasses, heating elements, columns, or quartz tubing